Customize Consent Preferences

We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.

The cookies that are categorized as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. ... 

Always Active

Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.

No cookies to display.

Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.

No cookies to display.

Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.

No cookies to display.

Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.

No cookies to display.

Advertisement cookies are used to provide visitors with customized advertisements based on the pages you visited previously and to analyze the effectiveness of the ad campaigns.

No cookies to display.

SHEAR WALL DESIGN CALCULATION

Shear walls are critical component of lateral load resisting system of a building structure, and they help to take forces from wind & earthquake.

[1] Generally, shear walls in a building need to take the vertical loads (linear or point), horizontal load & high in-plane moments produced by lateral forces.

[2] The vertical force induces a uniform compressive stress in the shear wall and the horizontal force & moment induces a push-pull effect, generating tension on one side and compression on another.

[3] The overall stress pattern of shear wall is linear in nature with most area in compression and less or no area in tension. (Length of compression & tension region depends upon actual moment & vertical forces).

[4] The tension region forms the boundary element in shear wall and is detailed with closely spaced vertical bars and confined reinforcement.

Whereas the rest of the wall is ensured the compression stress which are being induced.

[5] The extreme compressive area is also checked so that the stress is less than the design compressive stress.

The calculations & relevant expressions are shown in the image below. Additional checks are to be carried out which have openings in them.

This is a post on shear wall design calculation, any comments or suggestions are welcomed.